What size circuit breakers does a home need? Cable sizes, RCDs and the consumer unit

The Journal · Oct 7, 2026

What size circuit breakers does a home need? Cable sizes, RCDs and the consumer unit

Written by Engin Demirel · Electrical technician, master instructor · 12 years of experience

Short answer: In homes, lighting circuits typically use a 10 A breaker with 1.5 mm² cable and socket circuits a 16 A breaker with 2.5 mm² cable. Large loads such as ovens, hobs, air conditioners, water heaters and EV chargers each get their own circuit. The breaker protects the cable, so its rating must not exceed what the cable can carry. A 30 mA residual current device (RCD) is also needed to protect people. Values below are typical IEC practice; local wiring rules always take precedence.

Breaker and cable by circuit (typical values)

  • Lighting: 10 A – 1.5 mm²
  • Sockets: 16 A – 2.5 mm²
  • Washing machine / dishwasher, air conditioner, water heater: own circuit, 16 A – 2.5 mm²
  • Built-in oven: own circuit, 16 A – 2.5 mm² or 20 A – 4 mm² per the rating plate
  • Electric hob: per the manufacturer's wiring diagram; often 32 A – 6 mm² single-phase or 3 × 16 A three-phase
  • EV charging (7.4 kW single-phase): own circuit, 32 A – 6 mm²; 11 kW three-phase: 3 × 16 A – 5 × 2.5–4 mm²

These values are for short to medium runs. Longer runs increase voltage drop and need a larger cable; installation method (in conduit, grouped, hot surroundings) also reduces current-carrying capacity. The final choice is made by calculation.

Breaker size for sockets, lighting and the main switch

CircuitBreakerCableNote
Lighting10 A (C or B)1.5 mm²Check voltage drop on long runs
Room and living-room sockets16 A (C)2.5 mm²Max 10 A on old 1.5 mm² wiring
Kitchen worktop sockets16 A (C)2.5 mm²Separate from room sockets
Large appliances (oven, hob, air conditioner, water heater, white goods)Per appliance2.5 mm² for 16 A, 4 mm² for 20 AEach on its own circuit
Main switch in the consumer unitHigher than the circuit breakersPer supply cableMain fuse depends on contracted capacity (below)

These are typical IEC values; local rules (for example BS 7671 in the UK) take precedence. The rule never changes: the breaker rating must not exceed what the cable can carry. Breaker and cable values for each appliance (water heater, oven, hob, air conditioner, washing machine, dishwasher) are in which breaker for which circuit. For runs over 20–30 m, check the size with a cable size calculation; curves are explained in B vs C type breakers.

B and C curve breakers

The letter shows how much inrush current the breaker tolerates. A B curve trips instantly at 3–5 times its rating, a C curve at 5–10 times. Because LED drivers and motors have high inrush currents, C curve breakers are common in homes; B curve suits long runs and low fault currents.

Residual current device (RCD)

An RCD disconnects the circuit when current leaks to earth, for example through a person touching a live part. Homes use 30 mA RCDs, required by wiring regulations in most countries, including Turkey. Choose type A over the basic AC type, as it also detects pulsating DC leakage from electronics. EV charging needs a type B RCD, or a charger with 6 mA DC leakage detection plus a type A RCD.

Why does a breaker trip?

  • Overload: several powerful appliances on one circuit (heater + kettle + oven). Fix: move the load or add a circuit.
  • Short circuit: damaged cable, wet socket, faulty appliance. The breaker trips immediately; if it will not reset, have the wiring checked.
  • If the RCD trips: a damp junction box or socket, or a faulty appliance with a heating element (washing machine, water heater) are the usual causes. Unplug appliances one by one to find the fault.
  • Fitting a larger breaker is not a fix: the cable overheats and becomes a fire risk.

What size should the main fuse be?

The main (service) fuse is set by the network operator according to your contracted capacity, and it is sealed, so you cannot upsize it yourself. Typical homes have 25–40 A single-phase in Turkey; in the UK 60–100 A is common. Rough power: 40 A single-phase ≈ 9.2 kW, 3 × 40 A three-phase ≈ 27.7 kW.

The main switch or main breaker in your consumer unit is rated higher than the circuit breakers, so a fault trips only its own circuit and the rest of the house stays on (selectivity). Before adding an EV charger, heat pump or instantaneous water heater, check that the main fuse and contracted capacity are enough.

Where each breaker rating is used

  • 6 A: doorbells, control circuits, small LED driver circuits.
  • 10 A: lighting circuits (1.5 mm²).
  • 16 A: socket circuits, white goods, water heaters, small air conditioners (2.5 mm²).
  • 20 A: ovens, larger air conditioners, heavier appliance circuits (4 mm²).
  • 25 A: larger water heaters, main fuse in small homes (4–6 mm²).
  • 32 A: electric hobs, 7.4 kW EV charging, main fuse in homes (6 mm²).
  • 40 A: main fuse in homes, instantaneous water heaters, sub-board supply (10 mm²).
  • 50–63 A: main fuse for large houses, shops and workshops, three-phase sub-board supply (10–16 mm²).

See our circuit breakers category.

What a good consumer unit looks like

  • Every circuit is labelled ("Living room sockets", "Kitchen oven" etc.).
  • Splitting circuits across several RCDs (or RCBOs per circuit) stops one fault from blacking out the whole home.
  • A surge protection device (SPD) protects electronics from lightning and grid surges.
  • Leave spare ways for a future EV charger, air conditioner or solar system.

Your supply capacity is set by the distribution company; large loads like EV charging may need a capacity increase or a three-phase supply. Wiring and consumer unit work must be done by a qualified electrician.

In Bursa, ENGN provides electrical installation, consumer unit upgrades and EV charger installation.

Frequently asked questions

What breaker size for a socket circuit?

Socket circuits typically use a 16 A breaker with 2.5 mm² cable; lighting circuits 10 A with 1.5 mm². Local rules apply.

How many amps can 2.5 mm² cable carry?

In home wiring, 2.5 mm² cable is usually protected by a 16 A breaker. Run length, installation method and ambient temperature change its capacity.

Should I use a B or C curve breaker?

C curve is common in homes as it tolerates the inrush current of LED drivers and motors. B curve is preferred on long runs.

Is an RCD mandatory?

30 mA RCD protection is required for homes in most countries, including Turkey. Type A is recommended.

What should I do if a breaker keeps tripping?

Reduce the load on that circuit; if it continues there may be a short circuit or a faulty appliance. Never fit a larger breaker; have an electrician check it.

What breaker does an EV charger need?

A 7.4 kW single-phase charger needs its own circuit with a 32 A breaker and 6 mm² cable; 11 kW three-phase needs 3 × 16 A, plus type B or 6 mA DC leakage protection.

What size should a home's main fuse be?

The network operator sets it according to your contracted capacity. Typical values are 25–40 A single-phase in Turkey and 60–100 A in the UK. The main switch in the consumer unit is rated higher than the circuit breakers.