Downlight sizes: cut-out diameter, depth, spacing and how many you need
The Journal · Oct 7, 2026
Downlight sizes: cut-out diameter, depth, spacing and how many you need
Written by Engin Demirel · Electrical technician, master instructor · 12 years of experience
Short answer: The most common downlight cut-out diameters are 55, 65, 75, 85, 95, 105 and 150 mm; the exact size is listed on each product page as the mounting (cut-out) dimension. A plasterboard ceiling needs a void at least 1–2 cm deeper than the fitting. In living rooms and bedrooms, downlights are usually spaced 1–1.5 m apart and 50–60 cm from the wall. A 20 m² living room needs roughly 9 downlights of 7 W (about 600 lm).
Cut-out sizes
- 55–65 mm: small accent lights and GU10 holders.
- 75–95 mm: the most common residential COB downlights (5–12 W).
- 105–150 mm: wide-beam downlights for shops and offices.
- 200 mm and up: large downlights for high ceilings and commercial spaces.
Check the cut-out and body height before drilling. A hole only a few millimetres too large leaves the springs nothing to grip; too small and the fitting will not go in. Square downlights need a square cut-out.
Downlight size chart: cut-out, outer diameter and wattage
| Cut-out (hole) size | Outer diameter (approx.) | Typical power | Where |
|---|---|---|---|
| 55 mm | 65–70 mm | 3–5 W | Mini accent spot, niche, cabinet |
| 65–70 mm | 80–85 mm | 5–7 W | GU10 / MR16 spot fitting |
| 75 mm | 85–90 mm | 5–7 W | Home COB spot, hallway |
| 85 mm | 95–100 mm | 7–10 W | Living room, bedroom, kitchen |
| 95 mm | 105–110 mm | 9–12 W | Living room, shop |
| 105–120 mm | 120–135 mm | 12–18 W | Wide-beam downlight, office |
| 150–175 mm | 170–190 mm | 18–24 W | Shop, high ceiling |
| 200 mm and up | 220 mm + | 25–40 W | Commercial, very high ceiling |
GU10 and MR16 lamps have a standard size (50 mm); the fitting's cut-out is usually 65–75 mm. Square spots need a square cut-out (e.g. 75 × 75 mm, 85 × 85 mm). The table shows typical values; always check the product's mounting dimension before drilling.
Ceiling void and heat
The body and driver sit inside the ceiling. Add 1–2 cm to the body height; if the driver is separate, place it beside the fitting in free air, not on top of insulation. Heat decides LED life: a downlight buried in mineral wool or foam runs hot and fails early.
Spacing and distance from walls
- Between lights: in homes with 2.6–2.8 m ceilings, usually 1–1.5 m. Wide beams (60° and up) allow wider spacing, narrow beams (24–36°) need closer spacing.
- From walls: 50–60 cm (40–50 cm on a low 2.4–2.6 m ceiling). To wash a wall (curtains, art, textured walls) use 30–40 cm and adjustable downlights; lights too close to the wall cast sharp scallops.
- Layout: arrange downlights around seating and work areas rather than in a single line down the middle, and do not drill until the furniture plan is fixed.
How far apart should downlights be? (table)
Rule of thumb: on a 2.5–3 m ceiling, 60° spots go about 1–1.5 m apart and narrow-beam spots closer; distance from the wall is about half the spacing, usually 50–60 cm.
| Ceiling height | Spacing (60° spot) | Spacing (36° spot) | From the wall |
|---|---|---|---|
| 2.4–2.6 m | 100–120 cm | 70–90 cm | 40–50 cm |
| 2.7–2.9 m | 120–150 cm | 90–110 cm | 50–60 cm |
| 3.0–3.5 m | 150–180 cm | 110–130 cm | 60–80 cm |
In kitchens, spots in front of the worktop go 80–120 cm apart and slightly in front of the worktop edge; in hallways a single row 120–150 cm apart.
How many downlights per room? (table)
| Room | Target illuminance | Light needed | 600 lm (≈7 W) spots |
|---|---|---|---|
| 10 m² room | 150 lux | ≈ 2,500 lm | 5 |
| 15 m² room | 150 lux | ≈ 3,800 lm | 7 |
| 20 m² room | 150 lux | ≈ 5,000 lm | 9 |
| 30 m² room | 150 lux | ≈ 7,500 lm | 13 |
| 10 m² kitchen | 300 lux | ≈ 5,000 lm | 9 |
To plan layout and number by floor plan, see our lighting calculation guide; products are in spotlights.
How many downlights?
Simple calculation: required lumens ≈ area (m²) × target lux ÷ 0.6.
- Living room: 150 lux, bedroom: 100 lux. 20 m² living room: 20 × 150 ÷ 0.6 ≈ 5,000 lm → 5,000 ÷ 600 ≈ 8.3 → 9 downlights of 600 lm (always round up). 20 m² bedroom: 20 × 100 ÷ 0.6 ≈ 3,300 lm → 6 downlights.
- Kitchen worktop and work areas: 300–500 lux.
- Hallway: 100 lux; a single row 1.2–1.5 m apart.
- Bathroom: around 200 lux, with IP44 or higher downlights in wet areas.
Layering downlights with cove lighting and floor lamps is more comfortable than downlights alone; dimmable downlights let you lower the light in the evening.
Beam angle and colour
- 24–36°: accents, artwork, kitchen islands.
- 60°: the most common angle for general lighting.
- 90° and up: soft general light with low ceilings.
- Colour: 2700–3000 K at home, 3000–4000 K in kitchens and work areas; choose CRI 90 for true colours.
- Glare: deep-set downlights or honeycomb louvres avoid dazzle.
In Bursa, ENGN provides downlight layout plans, product selection and installation for homes and businesses.
- → Downlights
- → Track spotlights
- → Magnetic track vs track spotlights
- → How to make cove lighting
- → Lumens, watts and colour temperature
- → Our lighting store in Bursa (Nilüfer)
- → LED Panels
- → ENGN Vion recessed GU10 downlight: round, square and twin, 8 colours (our own design and production)
Frequently asked questions
What size hole does a downlight need?
Common cut-outs are 55, 65, 75, 85, 95, 105 and 150 mm. Residential COB downlights are mostly 75–95 mm; the exact size is on the product's mounting dimension.
How far apart should downlights be?
Usually 1–1.5 m in homes with 2.6–2.8 m ceilings. Wide beams allow wider spacing, narrow beams need closer spacing.
How far from the wall should downlights be?
50–60 cm for general lighting (40–50 cm on a low ceiling); 30–40 cm with adjustable downlights to wash a wall.
How many downlights for a 20 m² living room?
About 5,000 lumens for 150 lux, so roughly 9 downlights of 600 lumens (≈7 W; 8.3 rounded up).
How much ceiling void does a downlight need?
1–2 cm more than the fitting's body height. Do not cover the downlight or driver with insulation.
Which beam angle should I choose?
60° for general lighting, 24–36° for accents and artwork, and 90° or more for soft light with low ceilings.
What are standard downlight sizes?
Common cut-out sizes for recessed spots are 55, 65, 75, 85, 95, 105 and 150 mm. Homes mostly use 75–95 mm cut-outs and 5–12 W spots; the outer diameter is 10–15 mm larger than the cut-out.
How far apart should ceiling spotlights be?
With a 2.6–2.8 m ceiling, 60° spots go 100–150 cm apart and narrow-beam (36°) spots 70–110 cm apart. Keep them 50–60 cm from the wall.
What cut-out size does a GU10 spot need?
A GU10 lamp is 50 mm across; recessed GU10 fittings usually need a 65–75 mm cut-out. The exact size is on the fitting's product page.
How many spotlights does a 10 m² room need?
A 10 m² bedroom needs about 1,700 lm at 100 lux, so 3 spots of 600 lm (≈7 W). A study at 150 lux needs about 2,500 lm, so 5 spots; a kitchen worktop at 300 lux about 5,000 lm, so 9 spots.