Single-phase vs three-phase power: what is the difference and when do you need three-phase?

The Journal · Oct 7, 2026

Single-phase vs three-phase power: what is the difference and when do you need three-phase?

Written by Engin Demirel · Electrical technician, master instructor · 12 years of experience

Short answer: Single-phase power uses one phase and a neutral at 230 V; most homes are single-phase. Three-phase power has three phases with 400 V between them and carries about three times the power at the same current. Workshop machines, lifts, heat pumps, large air conditioners and 11–22 kW EV charging need three-phase. A single-phase home can charge at up to 7.4 kW (32 A).

What is single-phase? What is three-phase?

Single-phase power is carried by one phase and one neutral conductor; "phase" is the live conductor. Single-phase power is 230 V (in older references 220 V), and almost all sockets, lighting and household appliances run on it. A single-phase circuit has three wires: phase (L), neutral (N) and earth (PE).

Three-phase power is carried by three phase conductors (L1, L2, L3) shifted 120° from each other. Each phase to neutral is still 230 V, while phase to phase is 400 V (formerly 380 V). A three-phase circuit has five wires: three phases, neutral and earth. A three-phase board supplies both 400 V three-phase equipment and normal 230 V sockets.

Single-phaseThree-phase
Voltage230 V (phase–neutral)400 V (phase–phase), 230 V (phase–neutral)
Conductors3 (L, N, PE)5 (L1, L2, L3, N, PE)
Power at the same current1×about 3×
EV charging at homeup to 7.4 kW11 kW or 22 kW
Typical useflats, normal household usedetached houses, workshops, businesses, heat pumps, lifts

Amps to kW table: single-phase and three-phase

Approximate power by fuse or device current (power factor ≈ 1; for motors the real power is 10–20% lower):

CurrentSingle-phase (230 V)Three-phase (400 V)
10 A2.3 kW6.9 kW
16 A3.7 kW11 kW
20 A4.6 kW13.9 kW
25 A5.8 kW17.3 kW
32 A7.4 kW22 kW
40 A9.2 kW27.7 kW
63 A14.5 kW43.6 kW

How much a single-phase home can draw depends on the main fuse and the contracted connection power: about 5.8 kW with a 25 A main fuse and about 9.2 kW with 40 A. The distribution company sets the connection power; if you need more, you apply for an increase or a three-phase supply. To find out whether your home has three-phase, see does my home have three-phase.

Calculating power

  • Single-phase: Power = 230 V × current. 16 A ≈ 3.7 kW, 32 A ≈ 7.4 kW.
  • Three-phase: Power = √3 × 400 V × current (≈ 3 × 230 V × current). 16 A ≈ 11 kW, 32 A ≈ 22 kW.

Because three-phase carries the same power at lower current, cables stay thinner and voltage drop is lower. Motors also run more smoothly and efficiently on three-phase.

Wire colours

Under the current IEC standard: L1 brown, L2 black, L3 grey; neutral blue; protective earth green-yellow. A single-phase circuit has a brown phase, blue neutral and green-yellow earth. Older buildings may use other colours, so always measure before working.

Single-phase and three-phase EV charging

  • Single-phase 32 A: 7.4 kW. Charges a 60 kWh battery from 20% to 80% in about 5–6 hours.
  • Three-phase 16 A: 11 kW. The same charge takes about 3.5 hours.
  • Three-phase 32 A: 22 kW. Only helps cars that accept 22 kW AC; most cars are limited to 11 kW on AC.

If a car charges on one phase only, it will do so even on a three-phase charger. Check the car's AC charging power first, then the home's supply.

Upgrading a home to three-phase

A three-phase connection is requested from the distribution company (UEDAŞ in Bursa). The meter, main fuse and building riser may need replacing; in apartment blocks the riser capacity is checked. After the upgrade, single-phase circuits in the home are spread evenly across the three phases.

Phase balance

In a three-phase building, loads must be spread evenly across the phases. An overloaded phase trips its fuse, the neutral carries excess current and voltages become unbalanced. When adding large loads such as an EV charger, the consumer unit is rebalanced.

Which do I need?

  • Flat, normal household use, charging up to 7.4 kW: single-phase is enough.
  • Detached house, heat pump, large air conditioning, 11 kW charging, more than one car: three-phase.
  • Workshops, businesses, shared car parks: three-phase.

In Bursa, ENGN provides electrical installation, three-phase consumer units and EV charger installation.

Frequently asked questions

What is the difference between single-phase and three-phase?

Single-phase uses one phase and a neutral (230 V); three-phase has three phases (400 V between phases) and carries about three times the power at the same current.

How many kW is single-phase?

It depends on current: 16 A ≈ 3.7 kW, 32 A ≈ 7.4 kW. A home's total is limited by its contracted supply capacity.

How many kW is three-phase?

16 A three-phase ≈ 11 kW, 32 A three-phase ≈ 22 kW.

Do I need three-phase to charge an EV?

Single-phase is enough up to 7.4 kW. 11 kW and 22 kW AC charging need three-phase, and the car must support that power.

How do I get three-phase at home?

Apply to the distribution company (UEDAŞ in Bursa); the meter, main fuse and riser may need replacing. Internal circuits are then balanced across three phases.

What are the three-phase wire colours?

L1 brown, L2 black, L3 grey, neutral blue, earth green-yellow (IEC). Older installations may differ.

What is single-phase power?

Single-phase power is carried by one phase and one neutral conductor. It is 230 V; most homes, sockets and lighting are single-phase. A single-phase circuit has three wires: phase, neutral and earth.

What voltage is single-phase?

Single-phase power is 230 V (often still called 220 V). It is the voltage between phase and neutral.

What voltage is three-phase?

In three-phase, the voltage between two phases is 400 V (formerly 380 V); between each phase and neutral it is 230 V. That is why a three-phase board also supplies normal 230 V sockets.

How many kW is three-phase 16 amps?

Three-phase 16 A is about 11 kW (√3 × 400 V × 16 A). That is why 11 kW home chargers run on a three-phase 16 A circuit; three-phase 32 A is about 22 kW.

How many kW can a single-phase supply handle?

It depends on the main fuse and contracted power: a single-phase home with a 25 A main fuse can draw about 5.8 kW, 32 A about 7.4 kW and 40 A about 9.2 kW. A single 16 A socket circuit carries about 3.7 kW.